Technical data

ACNR Tone Cadence (PGM 441) A-168
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
ACNR Tone Cadence (PGM 441)
ACNR Tone Cadence can be adjusted (refer to Table for attribute values).
1. Press the [PGM] button and dial 441
2. Press the desired Flex button 1-5 (refer to Table).
Flex 1: Tone Cadence ON
Flex 2: Tone Cadence OFF
3. Use the dial pad to enter desired data.
4. Press the [SAVE] button to store the data entry.
DB INITIALIZATION (PGM 499)
1. Programmed database can be initialized selectively to default
2. Press the [PGM] button and dial 499.
3. Press the Flex button for the desired Attribute (refer to Table).
4. Use the dial pad to enter the required range if needed.
5. Press the [SAVE] button to initialize the selected database.
PGM 441 BTN RANGE DEFAULT
DIAL TONE CADENCE -- ACNR Dial Tone Cadence. 1 0-255 -
RINGBACK TONE CADENCE -- ACNR Ringback Tone Cadence 2 0-255 -
BUSY TONE CADENCE -- ACNR Busy Tone Cadence 3 0-255 -
ERROR TONE CADENCE -- ACNR Error Tone Cadence 4 0-255 -
LCR DIAL TONE CADENCE -- ACNR LCR Tone Cadence 5 0-255 -
PGM 499 BTN RANGE DEFAULT
INIT STATION DATA -- Initializes Station-based data
(except flexible button data),
1 Desired station range
(initialize whole data
when no range)
-
INIT STATION DATA -- Initializes Station-based data
(except flexible button data),
2 Desired station range
(initialize whole data
when no range)
-
Release 1.0