Technical data

GAIN & CADENCE CONTROL - PGM 400-440 A-154
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
GAIN & CADENCE CONTROL - PGM 400-440
DKT RX Gain (PGM 400)
The RX gain of DKT can be adjusted (refer to Table for setting values).
1. Press the [PGM] button and dial 400.
2. Press the desired Flex button (refer to Table).
3. Use the dial pad to enter desired data for the attribute setting (refer to Table).
4. Press the [SAVE] button to store the data entry.
SLT RX Gain (PGM 401)
The RX gain of SLT can be adjusted (refer to Table for setting values).
1. Press the [PGM] button and dial 401.
2. Press the desired Flex button (refer to Table).
3. Use the dial pad to enter desired data for the attribute setting (refer to Table).
4. Press the [SAVE] button to store the data entry.
PGM 400 BTN RANGE DEFAULT
DKT RX GAIN -- DKT RX gain from DKT. 1 0-63 26
DKT RX GAIN -- DKT RX gain from SLT. 2 0-63 22
DKT RX GAIN -- DKT RX gain from DECT. 3 0-63 26
DKT RX GAIN -- DKT RX gain from IPDEV. 4 0-63 26
DKT RX GAIN -- DKT RX gain from Analog CO. 5 0-63 26
DKT RX GAIN -- DKT RX gain from Digital CO. 6 0-63 33
DKT RX GAIN -- DKT RX gain from VMIB. 7 0-63 29
DKT RX GAIN -- DKT RX gain from DTMF. 8 0-63 08
DKT RX GAIN -- DKT RX gain from TONE. 9 0-63 32
DKT RX GAIN -- DKT RX gain from MUSIC. 10 0-63 29
PGM 401 BTN RANGE DEFAULT
SLT RX GAIN -- SLT RX gain from DKT. 1 0-63 32
SLT RX GAIN -- SLT RX gain from SLT. 2 0-63 32
Release 1.0
November 2010