Technical data
GK Setup Info (PGM 363) A-153
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
GK Setup Info (PGM 363)
1. Press the [PGM] button and dial 363.
2. Press the desired Flex button, refer to the following Table.
3. Press the [SAVE] button to store the new data.
PGM 363 BTN RANGE DEFAULT
GK USAGE -- Determines if MPB will be used as a GateKeeper. 1 0:Off
1:On
Off
LIGHT RRQ USAGE -- The System can be set to use the simple
Registration Request (RRQ) message (ON) or the full RRQ
message (OFF).
20:Off
1:On
Off
MULTI GK IP -- Multi-cast IP address for RAS Information of
Gatekeeper.
3 IP Address 0.0.0.0
MULTI GK PORT -- Multi-cast IP Port for RAS Information of
Gatekeeper.
4 IP Port #
(0-999)
0
UNI GK IP -- Uni-cast IP address for RAS Information of
Gatekeeper.
5 IP Address 0.0.0.0
UNI GK PORT -- Uni-cast IP Port for RAS Information of
Gatekeeper.
6 IP Port #
(0-999)
1719
KEEP ALIVE TIME -- The System will cycle a polling message at
the culmination of the KEEP ALIVE TIME (sec.) to verify the
status of the connection.
7 1-1000 120
GATEWAY PREFIX -- The Numbering Plan for Calling Number in
RAS Setup.
8 Max 25 digits -
H.323 GATEWAY ID -- The GateKeeper ID (Keyset Admin=up to
24 digits can be checked or programmed).
9 Max 129 digits -
Release 1.0
November 2010