Technical data
FoPSTN Attributes (PGM 333) A-149
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
FoPSTN Attributes (PGM 333)
The Fail-over function allows the systems in a Centralized Control network (TNET) environment
to complete calls from System to System over a PSTN (analog or digital) line should the WAN
connection to the CM fail. A CO gateway Module must be registered to the LM for local control
and access to CO services. Users may call others in the normal manner and the call is routed
over CO facilities to the remote CM. When calls are directed to a DID line at the receiving
system, the system will select a line from the assigned CO Group and dial the Tel Number with
the station number dialed as the trailing digits.
1. Press the [PGM] button and dial 333.
2. Press the Flex 1-3 for the desired setting (refer to Table).
Flex 1: Enable or disable FO.
Flex 2: Press the [SAVE] button to reset the FO Table.
Flex 3: dial the Table bin number to input data.
3. For Flex 3, use the dial pad to enter the required data (refer to Table).
4. Press the [SAVE] button to store the new data.
PGM 333 BTN RANGE DEFAULT
ENABLE FoPSTN -- Determines if Fail-over operation is
enabled or disabled from the CM or LM.
10:Off
1:On
-
INIT FoPSTN TABLE -- Determines how to initialize the FO
Table.
2- -
FoPSTN Attributes 3 1-100 (MBX IP-100)
1-200 (MBX IP-300)
-
FoPSTN NUM PLAN -- Station numbers associated with
the remote System.
3-1 Max 16 -
FoPSTN CO GROUP -- Determines the CO Group of the
Local System that will be used to place calls to the stations
entered in the FO Numbering Plan, should a WAN failure
occur.
3-2 1-24 (MBX IP-100)
1-72 (MBX IP-300)
-
FoPSTN TEL NUMBER -- Determines the telephone
number the System should dial to place a call to the
Stations entered in the FO Numbering Plan, should WAN
failure occur.
3-3 Max 10 -
T