Technical data

ISDN Board - Clock Priority (PGM 301) A-144
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
ISDN Board - Clock Priority (PGM 301)
In the MBX IP System, Clock synchronization is controlled by the pre-programmed ISDN Clock
priority. The first ISDN board becomes the Clock Master board, and if some error occurs to the
Clock Master board, the next board automatically takes on the role as Clock Master. After the
original master board recovers, the Clock Master board is changed again. If there is no
available ISDN board to become a Clock Master board, the System is synchronized with the
internal clock.
1. Press the [PGM] button and dial 301.
2. Use the dial pad to enter the desired Slot Numbers.
3. Press the [SAVE] button to store the new data.
IPP Board Attribute (PGM 305)
The VOIB, and VMIB boards have some attributes that can be programmed by the
Administrator.
1. Press the [PGM] button and dial 305.
2. Enter desired Slot Number with 2 digits.
3. Press the Flex 1-6 for the desired setting (refer to Table).
4. Use the dial pad to enter the required data.
5. Press the [SAVE] button to store the new data.
T1 WINK TIME -- T1 Wink time. 13 7-15 10
T1 SEIZE TIME -- T1 seize time. 14 0-127 3
T1 RLS TIME -- T1 release time. 15 0-127 7
T1 RING DET TIME -- T1 ring detect time. 16 2-9 2
T1 RING STOP TIME -- T1 ring stop time. 17 10-60 60
PGM 305 BTN RANGE DEFAULT
IP ADDR -- IP Address of selected slot, 1 IP Address 10.10.10.#
(#:slot number)
ROUTER IP ADDR -- Router IP Address of selected slot. 2 IP Address 0.0.0.0
SUBNET MASK -- Subnet Mask of selected slot. 3 IP Address 255.255.255.0
PGM 300 BTN RANGE DEFAULT
Release 1.0
November 2010