Technical data
LCR Time Table Attributes (PGM 255) A-112
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
LCR Time Table Attributes (PGM 255)
The LCR Time Tables provide a mechanism to define the database with Digit Conversion Table
(PGM251-252), which will route outgoing calls, particularly long distance, using the most
cost-effective route.
Additionally, days of the week are grouped into zones (Day Zones) and the time of day can be
set into three groups (Time Zones). The PGM 255 table provides general descriptive
information and input ranges.
1. Press the [PGM] Button and dial 255
2. Press Flex button 1-4, refer to the Table.
3. For LCR Time Zones, use the dial pad to enter desired data. Refer to the Table for input
ranges.
- Flex 1-7: to select the day of week (1=Monday, 7=Sunday).
4. Enter the desired Day Zone (1-3).
5. Press the [SAVE] button to store the data entered.
Saturday DAY/NIGHT/TIMED ring mode start times and TIMED
mode end times.
6 0000-2359 Day: 9:00
Nite: 18:00
TDS: _-_
TDE: _-_
Sunday DAY/NIGHT/TIMED ring mode start times and TIMED mode
end times.
7 0000-2359 Day: 9:00
Nite: 18:00
TDS: _-_
TDE: _-_
PGM 255 BTN RANGE DEFAULT
DAY ZN -- For each day of the week, a Day Zone (1 to 3) is
assigned. The active Day Zone is the Zone assigned to the current
day of the week (Flex button 1-7).
1 FLEX 1-7
+ 1-3
Zone 1: All days
of the week
DAY ZONE 1 -- This entry defines the time zone of day zone 1
when Day Zone 1 is active.
2 00-24 00-24
DAY ZONE 2 -- This entry defines the time zone of day zone 2
when Day Zone 2 is active.
3 00-24 -
DAY ZONE 3 -- This entry defines the time zone of day zone 3
when Day Zone 3 is active.
4 00-24 -
PGM 254 BTN RANGE DEFAULT
Release 1.0
November 2010