Technical data

RS-232 Port Settings (PGM 230) A-92
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
RS-232 Port Settings (PGM 230)
The system has one RS 232 serial port located on the MPB. Certain characteristics of the port
are programmable: Baud rate, RS 232 control, and Page settings (refer to Table for a
description of the settings, the data entries required and LCD displays).
1. Press the [PGM] button and dial 230.
2. Select the desired Flex button, refer to the following Table.
3. Use the dial pad to enter the desired Port data.
4. Press the [SAVE] button to store the Port Data entry.
VMIB MOH -- assigns the VMIB Prompt index of
VMIB Slot YY for VMIB MOH X.
3-6 for MPB300
(3-5 for MPB100)
01-70 -
SLT MOH -- assigns the SLT ports for SLT
MOH.
7-11 for MPB300
(6-10 for MPB100)
--
PGM 230 BTN RANGE DEFAULT
BAUD RATE -- Establishes the BAUD rate for the RS-232 serial port. 1 1: 9600
2: 19200
3: 38400
4: 57600
5: 115200
5:115200
PAGE BREAK -- The system can send a page break command over
the serial port at the end of each page.
20:Off
1:On
0:Off
LINE PER PAGE -- Determines Page length, the number of lines the
system will send before sending a Page break.
3 001-199 66
XON/XOFF -- Enables XON/XOFF protocol. 4 0:XOff
1:XOn
0:XOff
PGM 229 BTN RANGE DEFAULT
Release 1.0
November 2010