Technical data

CO/IP Call Time Restriction 3-40
Chapter 3: System Features
MBX IP Description / Operations & Programming Guide
CO Line Group (PGM 160 - FLEX 3-4) … see details on page A-47
H.323 Data
H.323 Routing Attribute (PGM 360) … see details on page A-150
Station Data
CO Group Access (PGM 150) … see details on page A-45
CO/IP Call Time Restriction
The System can be programmed to limit the length of calls at specified stations. When a
specified Station places a call, the system initiates the Call Restrict timer, and 15 seconds prior
to timer expiration, a warning tone is delivered. At expiration, the system terminates the call
returning the external CO/IP line to idle.
Call time restriction can be applied differently according to call types (Local call, Long Distance
call or international call).
CONDITIONS
- The warning tone can be provided periodically or once as programmed.
- Once activated, the Call Warning Tone timer continues timing while the call is
connected to the system even if the call is transferred or picked up at another station.
PGM 160 BTN RANGE DEFAULT
OUTGOING GRP NO -- Set CO Group Number to
apply to outgoing calls.
3 01-72, none (MBX IP-300)
01-24, none (MBX IP-100)
01
INCOMING GRP NO -- Set CO Group Number to
apply to incoming calls.
4 01-72, none (MBX IP-300)
01-24, none (MBX IP-100)
01
PGM 360 BTN RANGE DEFAULT
DIGIT (1) -- destination numbers associated with the H.323 routing
system.
1 Max 8 digits -
DEST IP ADDR -- destination IP address associated with the H.323
routing system.
2 - 0.0.0.0
Release 1.0