Technical data

Station Group Greeting/Queuing Attributes (PGM 201) A-68
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
Station Group Greeting/Queuing Attributes (PGM 201)
Each type of group has a different set of available attributes relating to the greeting and queuing
announcements, time. Refer to the table below for the descriptions of the attributes, LCD
displays and data entries required.
1. Press the [PGM] button and dial 201.
2. Use the dial pad to enter the desired Station Group number (620-639 for the MBX IP 100
and 620-669 for MBX IP 300).
3. Press the Flex button for the desired attribute; refer to the following Table.
4. Use the dial pad to enter the desired Group Attributes data, refer to the following Table.
TENANT NO -- this entry assigns a tenant of a station group. 3 1-9 (MBX IP-300)
1-5 (MBX IP-100)
1
TIME TABLE IDX -- Time Table index, 4 1-9 1
PICKUP OPTION -- stations can pickup group calls ringing at
other stations in the group.
50: Disable
1: All Call
2: Intercom
3: External
Disable
MEMBER ASSIGN -- this entry assigns stations as members
of a station group.
6- -
PGM 201 BTN RANGE DEFAULT
GREETING TYPE -- this entry defines the type of greeting
tone.
11: Normal
2: Prompt
3: Annc
4: INT MOH
5: EXT MOH
6: VMIB MOH1
7: VMIB MOH2
8: VMIB MOH3
9: VMIB MOH4
10: SLT MOH1
11: SLT MOH2
12: SLT MOH3
13: SLT MOH4
14: SLT MOH5
1
GREETING PLAY -- this entry defines greeting play time. 2 000-180 (secs) 000
PGM 200 BTN RANGE DEFAULT
Release 1.0
November 2010