Technical data

CO Group Access Code Attribute (PGM 180) A-65
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
PGM 180 BTN RANGE DEFAULT
ACCESS CODE NAME -- When a CO Grp
Access code is dialed or Flex Button is pressed;
name is displayed on the station's LCD.
1 Max 16 chars -
CO LINE CHOICE -- Decide to select to CO line
priority to seize. NOTE: When Outgoing Group
Number is not assigned, this option is not applied.
2 0: Round Robin
1: Last Line
2: First Line
Last Line
OUTGOING GRP NO -- Determines the CO
Group number used to seize. NOTE: If not
assigned, the access code is used as LOOP key.
3 01-72 (MBX IP-300)
01-24 (MBX IP-100)
Not assigned to the
first access code.
01-72 (MBX IP-300)
01-24 (MBX IP-100)
is assigned
sequentially from the
second access code
AND DGT -- Automatic Network Dialing (AND)
digit is sent after CO line seized. This feature
allows user to initiate CO calls only by dialing CO
Group Access Code.
4 Max 10 digits -
ARS SERVICE -- If Alternate Route Selection
(ARS) is set, ARS digit is dialed instead of CO
Group Access code when there is no available
path.
50: Off
1: On
Off
ARS DGT 1 -- Alternate CO Group Access code to
be used when original CO Group Access code
failed to find available CO line.
6 Max 8 digits -
ARS 1 OGR DGT -- When alternate CO Group
Access code is used, this field defines if original
digits or converted digits are used.
70: Off
1: On
Off
ARS DGT 2 -- Second alternate CO Group Access
code to be used when original CO Group Access
code and first ARS code failed to find available
CO line.
8 Max 8 digits -
ARS 2 OGR DGT -- When alternate CO Group
Access code is used, this field defines if original
digits or converted digits are used.
90: Off
1: On
Off
Release 1.0
November 2010