Technical data
CO Group Access Code Attribute (PGM 180) A-64
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
CO Group Access Code Attribute (PGM 180)
Each CO Group Access Code allows user to access the CO group using different codes and
different options.
1. Press the [PGM] button and dial 180
2. Use the dial pad to enter CO Grp Access Code. Access code can be edited in Numbering
Plan (PGM 113)
3. Press the desired Flex button; refer to the following Table.
4. Use the dial pad to enter desired data for the Attribute.
5. Press the [SAVE] button to store the data entry.
OUTGOING CALL TRANSFER RELEASE TYPE -- if outgoing
CO call can be transferred to other CO call, release type can
be set. If set to None, it is not disconnected.
30: None
1: Release after
Release Timer
None
OUTGOING
CALL TRANSFER RELEASE TIME -- if an
outgoing CO call is transferred to CO call and CO - to - CO call
is started, the call is disconnected after release time, when
release type is set to 'Rls after Rls Time'. Before disconnecting,
a warning tone is provided.
4 000-300 (sec) 060
INCOMING CALL TRANSFER DIRECTLY -- if this feature
is set to ON, CO incoming call can be transferred directly
without any stations or ATD to transfer the call.
5 0: Off
1: On
Off
STATION INCOMING
CALL TRANSFER -- while stations
are connected to incoming CO call of first CO Group, the
station can transfer the call to second CO group.
6 0: Off
1: On
On
ATD INCOMING CALL TRANSFER -- while ATD is
connected to incoming CO call of first CO Group, the ATD can
transfer the call to second CO group.
7 0: Off
1: On
On
INCOMING CALL TRANSFER RELEASE TYPE -- If incoming
CO call can be transferred to other CO call, release type can
be set. If set to None, it is not disconnected.
80: None
1: Release after
Release Timer
None
INCOMING
CALL TRANSFER RELEASE TIME -- If an
incoming CO call is transferred to CO call and CO - to - CO call
is started, the call is disconnected after release time, when
release type is set to 'Rls after Rls Time'. Before disconnected,
warning tone is provided.
9 000-300 (sec) 060
PGM 179 BTN RANGE DEFAULT
Release 1.0
November 2010