Technical data
CO Outgoing Inter-Digit Timer (PGM 174) A-61
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
CO Outgoing Inter-Digit Timer (PGM 174)
When making an outgoing LCO call, the time limit to enter digits can be adjusted. After timeout,
the voice path is automatically connected. This timer does not apply to digital CO lines.
1. Press the [PGM] button and dial 174.
2. Use the dial pad to enter a CO line range. For a single CO Line, enter the same number
twice. For MBX IP-100, acceptable range is 01-80, for MBX IP-300, the acceptable range
is 001-240.
3. Press the desired Flex button; refer to Following Table.
4. Use the dial pad to enter desired data for the Attribute.
5. Press the [SAVE] button to store the data entry.
PGM 174 BTN RANGE DEFAULT
SEIZE WAIT TIME -- wait time before first digit. 1 005-200 (100 msec) 020
FIRST DGT -- time limit between first digit and the next digit. 2 010-200 (100 msec) 100
SECOND DGT -- time limit between second digit and the
next digit.
3 010-200 (100 msec) 080
THIRD DGT -- time limit between third digit and the next
digit.
4 010-200 (100 msec) 070
FORTH DGT -- time limit between forth digit and the next
digit.
5 010-200 (100 msec) 060
FIFTH DGT -- time limit between fifth digit and the next digit. 6 010-200 (100 msec) 050
MORE THAN 6TH -- time limit between digit and the next
digit after the sixth digit.
7 010-200 (100 msec) 040
Release 1.0
November 2010