Technical data
CO Outgoing Attributes II (PGM 171) A-59
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
CO Outgoing Attributes II (PGM 171)
PGM 171 BTN RANGE DEFAULT
CPT DETECT -- If this feature is set to ON, CPT(Call Processing
Tone) is detected and the line can be dropped.
10: Off
1: On
On
UNSUP CONF EXTEND -- If this feature is set to ON,
Unsupervised Conf Timer can be extended by dialing feature
code after warning tone is heard.
20: Off
1: On
Off
PROVIDE RING BACK TN -- If this feature is set to ON, dummy
ring back tone is heard by system when CO line is seized.
30: Off
1: On
Off
BLF USAGE -- If this feature is set to ON, flex button LED will be
flashing when CO line is programmed on the button.
40: Off
1: On
On
RLS GUARD TIMER -- If CO release signaling is not completed
successfully, CO line is disconnected when the timer expires.
5 00-15 02
UNSUP CONF TIMER -- When there is conference call without
supervisor, or there is any CO-to-CO call, the call is
disconnected after the timer expires. The warning tone is heard
before the line is disconnected.
6 000-255 (min) 000
MAX TRANSFER RING TIMER -- Max. Ring Time when
outgoing CO is transferred/recalled.
7 001-300 (sec) 120
OUTGOING TIME TABLE -- The time Table index to be applied
to outgoing CO Calls
8 1-9, none none
Release 1.0