Technical data

CO Outgoing Attributes I (PGM 170) A-56
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
CO Outgoing Attributes I (PGM 170)
CO Outgoing Attributes define various characteristics of the CO lines under control of the
system when there is an outgoing CO call.
1. Press the [PGM] button and dial:
170 for CO Outgoing Attributes I
171 for CO Outgoing Attributes II
2. Use the dial pad to enter a CO Line range. For a single CO Line, enter the same number
twice. For MBX IP-100, acceptable range is 01-80, for MBX IP-300, the acceptable range
is 001-240.
3. Press Flex button to access desired menu. Refer to the following Table for each attributes.
4. Use the dial pad to change the value.
5. Press the [SAVE] button to store the changed data.
PGM 169 BTN RANGE DEFAULT
Incoming CO Alternataive
DAY --
1F1: Busy
F2: No Answer
F3: Invalid
F4: Transfer No Answer
F5: Recall No Answer
F6: DND
F7: Out Of Service
F8: Error
1: Disconnect
2: Attendant
3: CO Ring
4: Alt Ring Table
5: Tone
6: Pilot HuntGroup
Disconnect
1 sec
NIGHT -- 2 Disconnect
1 sec
TIMED -- 3 Disconnect
1 sec
Release 1.0
November 2010