Technical data

Station Number Attributes - PGM 131-135 A-33
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
Station Number Attributes - PGM 131-135
Station Number Attributes define features and functions available to the station number.
Generally, the entry will turn the feature ON (enable) or OFF (disable). Refer to the following
tables for a description of the features and the input required.
1. Press the [PGM] button and dial:
131 for Station Number Attributes 1
132 for Station Number Attributes 2
133 for Station Number Attributes 3
134 for Station Number Attributes 4
135 for Station Number CLI Attributes
2. Use the dial-pad to enter a station range (Ex. 100-110). For a single station, enter the
same number twice.
3. Press the desired Flex button; refer to the following Station Number Atrributes tables.
4. Use the dial-pad to enter desired data for the attribute setting, refer to the following Station
Number Atrributes tables.
5. Press the [SAVE] button to store the data entry.
Station Number Attributes I (PGM 131)
PGM 131 BTN RANGE DEFAULT
STATION NAME -- enables user name entry. The name is
displayed on the LCD of Digital Phones
1 Max 16 chars -
TENANT GROUP -- specify tenant group for station. 2 1-9 (MBX IP 300)
1-5 (MBX IP 100)
1
DIGIT CONVERSION TABLE -- specify Digit conversion table
for station.
31-9 1
PASSWORD -- restricts CO Call Duration to station. 4 0-12 digits -
BUSY SERVICE -- when an SLT extension attempts to transfer
a CO call to a CO line it is blocked and the call is released.
5 0:Busy Tone
1:Camp-on
2:Call Wait
3:Pilot Hunt
Busy Tone
CHARGE MODE -- permits station to receive pilot hunt ring. 6 0:Free
1:Report
Report
SMDR HIDDEN DIGIT -- sets Anonymous Call Restrict service. 7 0:Disable
1:Enable
Disable
Release 1.0
November 2010