Technical data

Station Port Attributes (PGM 121-124) A-26
Appendix A: System Programming Tables
MBX IP Description / Operations & Programming Guide
Station Attributes II (PGM 122)
LLCD LANGUAGE SELECTION
DUMMY TERMINAL -- this item defines whether a station is used for hot
desk terminal. If you want to use a station as hot desk, this field must be
set to ‘ON’.
80: Off
1: On
Off
PORT BLOCK -- if this value is set to ON, Station is blocked so it is
impossible to use that station.
90: Off
1: On
Off
GAIN TABLE IDX -- this feature allows 3 kinds of gain tables per station. 10 1-3 1
SLT LINE LENGTH -- this feature is used to distinguish the line length
when the distance between SLT station and SLIB board is too variable.
(Short:0km, Long:0-3km, Far:3-7.5km).
11 0: Short
1: Long
2: Far
Short
ALARM -- enable to receive system alarm signal. 12 0:Disable
1:Enable
Disable
DOOR OPEN -- enable to use door open feature. 13 0:Disable
1:Enable
Disable
PGM 122 BTN RANGE DEFAULT
LCD LANGUAGE -- sets the Language used in the
Station’s LCD.
1 (00-14) 00 (English)
LCD DATE MODE -- sets the Station’s Date display as
month/day or day/month.
20: DDMMYY
1: MMDDYY
DDMMYY
LCD TIME MODE -- sets the Time display mode as 12
hour or 24-hour (military) time.
3 0: 12 Hour Mode
1: 24 Hour Mode
12 hour
BACK LIGHT USAGE -- if a station can support LCD
backlight, you can set backlight usage option.
4 0: Always Off
1: Busy Only
2: Always On
3: Auto
4: Delayed Off
Busy Only
IP-8000 FONT -- IP 8000 Series terminal has two kinds
of font – Times New Roman and Gothic. This menu
determines what font is used.
5 0: Times New Rom
1: Gothic
Times New Rom
PGM 121 BTN RANGE DEFAULT
Release 1.0