Technical data

Attendant Recall 7-30
Chapter 7: Attendants
MBX IP Description / Operations & Programming Guide
Attendant Recall
Unanswered or Abandoned CO/IP Calls that remain unanswered for the Hold or Transfer Hold
Timer (as applicable), will Recall at the Station that placed the Call on Hold. If the Call remains
unanswered for the assigned Recall Time, the first available Attendant will also receive the
Recall. The Attendant and Station will simultaneously receive the recall signal for the Attendant
Recall Timer period after which the System will disconnect the Call and return the CO/IP Line
to Idle.
OPERATION
System
Attendant Recall operation is automatic.
PROGRAMMING
CO Line Data
Incoming CO Alternate (PGM 169) … see details on page A-55
PGM 169 BTN RANGE DEFAULT
Incoming CO Alternataive
DAY --
1F1: Busy
F2: No Answer
F3: Invalid
F4: Transfer No Answer
F5: Recall No Answer
F6: DND
F7: Out Of Service
F8: Error
1: Disconnect
2: Attendant
3: CO Ring
4: Alt Ring Table
5: Tone
6: Pilot HuntGroup
Disconnect
1 sec
NIGHT -- 2 Disconnect
1 sec
TIMED -- 3 Disconnect
1 sec
Release 1.0
November 2010