Technical data
CO Ring Detect 5-42
Chapter 5: CO/IP
MBX IP Description / Operations & Programming Guide
PROGRAMMING
CO Line Data
Incoming CO Release Guard Timer (PGM 166 - FLEX 8) … see details on page A-52
Outgoing CO Release Guard Timer (PGM 171 - FLEX 5) … see details on page A-59
System Data
LCO Release Guard Timer (PGM 221 - FLEX 6) … see details on page A-86
CO Ring Detect
The System incorporates timers for Ring-On and Ring-Off durations to assure proper alerting.
When the duration of the Ring Signal exceeds the Ring-On Timer, alerting will start. When the
Ring is not present for a period exceeding the Ring-Off Timer, alerting will stop. This allows the
System Ring cycle detection to be matched to the many and varied PBX systems.
CONDITIONS
- Ring-On time and Ring-Off time are assigned on a System basis.
- The CO Ring Detect is applied to Analog CO Lines only.
OPERATION
System
Operation of Ring detect is automatic.
PGM 166 BTN RANGE DEFAULT
RLS GUARD TIME -- If CO release signaling is not completed
successfully, CO line is disconnected when timer expires.
8 00-15 (sec) 01
PGM 171 BTN RANGE DEFAULT
RLS GUARD TIMER -- If CO release signaling is not completed
successfully, CO line is disconnected when the timer expires.
5 00-15 02
PGM 221 BTN RANGE DEFAULT
LCO RLS GUARD TMR -- when an analog CO Line is returned to
idle, the system will deny access for this time to assure the PSTN
returns the CO circuitry to idle.
6 00-60
(minutes)
010
Release 1.0
November 2010