Technical data
CO/IP Ring Assignment 5-39
Chapter 5: CO/IP
MBX IP Description / Operations & Programming Guide
PROGRAMMING
CO Line Data
CO Ring Table (PGM 167) … see details on page A-54
Table Data
System Time Table (PGM 253) … see details on page A-110
PGM 167 BTN RANGE DEFAULT
SERVICE TYPE -- If service type is set as 0-2,
ring option is applied to ring assigned stations.
Otherwise, if service type is set to 3, feature code
is activated on incoming call.
10: All Ring
1: First Idle
2: Circular
3: Feature Code
All Ring
FEATURE CODE -- If Service type is set to
Feature Code and valid feature code is
assigned, then assigned feature is activated
when there is an incoming call.
NOTE: Feature Code is not applied to rerouted
calls.
2 Valid Feature Code
(refer to PGM 115)
-
FEATURE DELAY -- If Service type is set to
Feature code, it can be delayed.
3 00-30 00
100 (0) -- Assigned station and delay value can
be displayed. Volume Up/Down key is used to
scroll data.
4- -
MEMBER ASSIGN -- To change station's ring
assign status, enter desired station range. (Max
30 stations can be assigned)
5 Start Station & End
Station
-
DELAY -- Enter delay value; if delay is 0, station
will start to ring immediately. If delay value is
deleted, the station will not ring.
Otherwise if delay is 1-9, the station will start to
ring after delay time(3 times of delay value)
5-1 0-9 Sta 100 (Port 0):delay 0
Others: not assigned
PGM 253 BTN RANGE DEFAULT
TIME ZONE COMMENT-- defines the comment of the Time
Table.
1 32 characters none
SYSTEM TIME ZONE -- defines the Time Zone of the Time Table 2 0-73 0: Sys Time
Release 1.0
November 2010