Technical data

CO/IP Ring Assignment 5-38
Chapter 5: CO/IP
MBX IP Description / Operations & Programming Guide
Outgoing CO Own Code (PGM 170 - FLEX 12) … see details on page A-56
Incoming CO Own Code (PGM 165 - FLEX 9) … see details on page A-51
CO/IP Ring Assignment
Each station in the system can be programmed to provide an audible signal when the system
detects an incoming call on specified CO/IP lines. Separate ring assignments are made for
Day, Night and Timed Ring operation mode. In addition, the audible signal at the station can
be delayed by 1 to 30 ring cycles allowing other stations to answer the call first.
CONDITIONS
- Separate assignments are made for Stations to ring in the Day, Night and/or Timed
Ring mode.
- Audible Alerting for an Incoming VoIP call is based only on the derived IP Address.
- A Busy Station receives Muted Ring or Call Waiting tones as appropriate for the
Station’s Off-hook Ring Assignment.
- The system Ring mode can be selected manually or automatically,
- Automatic mode: Day/Night selection is determined based on the Automatic Ring
Mode Selection table.
- Manual mode: The Attendant has manual control over the Ring mode selection.
- The LCD of the Attendant Station will display Night and Timed Ring Mode.
- If CO/IP Ring is assigned to only one Station and that Station assigns Call Forward,
the CO/IP Call will be routed according to Call Forward settings.
OPERATION
System
Operation of this feature is automatic.
PGM 170 BTN RANGE DEFAULT
REPRESENTATIVE CLI -- When 'Use Represent
CID'(PGM170-F10) is set to ON, representative CLI is sent when
making outgoing call regardless of other CLI attribute.
12 Max 16
digits
-
PGM 165 BTN RANGE DEFAULT
OWN CODE -- Own Code. 9 Max 16
digits
-
Release 1.0
November 2010