Technical data

CO Line Service 5-18
Chapter 5: CO/IP
MBX IP Description / Operations & Programming Guide
OWN CODE -- CO Own code can be inserted
before station number when making outgoing call
CLI.
13 Max 16 digits -
CLI TYPE -- CLI type can be selected.
If set to Long CLI, only selected long CLI data is
used instead of normal CLI.
14 0:Normal
1:Long CLI (PGM 135-F10)
2:Long CLI (PGM 135-F11)
3:Long CLI (PGM 135-F12)
Normal
TRANSIT CLI TYPE -- Transit CLI type can be
selected.
If set to transit CLI, only selected transit CLI data is
used instead of normal CLI.
15 0:Normal
1:CLI1 (PGM 165-F8)
2:CLI2 (PGM 165-F9)
3:CLI3 (PGM 165-F10)
Normal
CLI CONV. TABLE -- CLI Conversion Table index. 16 1-9, none none
REDIRECTION NUMBER -- Redirection number. 17 0: Off
1: On
Off
ACNR EXTEND TIMER -- ACNR extend timer. 18 00-99 00
PGM 171 BTN RANGE DEFAULT
CPT DETECT -- If this feature is set to ON, CPT(Call Processing
Tone) is detected and the line can be dropped.
10: Off
1: On
On
UNSUP CONF EXTEND -- If this feature is set to ON,
Unsupervised Conf Timer can be extended by dialing feature
code after warning tone is heard.
20: Off
1: On
Off
PROVIDE RING BACK TN -- If this feature is set to ON, dummy
ring back tone is heard by system when CO line is seized.
30: Off
1: On
Off
BLF USAGE -- If this feature is set to ON, flex button LED will be
flashing when CO line is programmed on the button.
40: Off
1: On
On
RLS GUARD TIMER -- If CO release signaling is not completed
successfully, CO line is disconnected when the timer expires.
5 00-15 02
UNSUP CONF TIMER -- When there is conference call without
supervisor, or there is any CO-to-CO call, the call is
disconnected after the timer expires. The warning tone is heard
before the line is disconnected.
6 000-255 (min) 000
PGM 170 BTN RANGE DEFAULT
Release 1.0
November 2010