Technical data

CO Line Service 5-11
Chapter 5: CO/IP
MBX IP Description / Operations & Programming Guide
Incoming CO Attributes (PGM 165-166) … see details on page A-51
INC/OUT MODE -- Each CO lines can be set
to only incoming call is allowed or outgoing is
allowed only.
9 0: Incoming Only
1: Outgoing Only
2: Allow Both
Both
DIALING TYPE -- Signal type can be selected;
DTMF, Pulse, R2MFC.
10 0: DTMF
1: PULSE
2: R2
DTMF
CHARGE MODE -- If 'FREE', the external call
though CO line is not printed/saved to SMDR
even though SMDR is enabled.
If 'REPORT', the external call though CO, line
is included to SMDR according to the SMDR
Attributes.
11 0: Free
1: Report
Report
METERING TYPE -- According to PSTN
service type, metering type can be selected
among 00-12 to manage call charge. 01-06
can be applied to LCO lines, 07-12 can be
applied to ISDN lines.
12 00: None
01: 12KHz
02: 16KHz
03: 50KHz
04: SPR
05: PPR
06: NPR
07: AOC 0(Standard)
08: AOC 1 (Italy & Spain)
09: AOC 2 (Finland)
10: AOC 3 (Australia)
11: AOC 4 (Belgium)
12: AOC 5 (Netherlands)
None
PGM 165 BTN RANGE DEFAULT
NAME -- incoming CO line name can be assigned. 1 Max 16 chars -
SCREEN INDICATOR -- determines if screen indicator
will be inserted in ISDN messages.
2 0: Off (user-provided,
not screened)
1: On (user-provided,
verified and passed)
Off
PGM 160 BTN RANGE DEFAULT
Release 1.0
November 2010