Technical data
CO Line Service 5-10
Chapter 5: CO/IP
MBX IP Description / Operations & Programming Guide
• Max Ring Time - System releases the CO Line if the transferred/held incoming CO line
is not answered prior to Timer Expiration.
CONDITIONS
- This feature can be set for each outgoing CO line.
PROGRAMMING
CO Line Data
CO Line Data (PGM 160) … see details on page A-47
PGM 160 BTN RANGE DEFAULT
CO TYPE -- Displays physical line type of
selected CO line.
1 Display Only -
SVC TYPE -- Set CO line type as DID or
Normal.
20:Normal
1:DID
Normal
OUTGOING GRP NO -- Set CO Group
Number to apply to outgoing calls.
3 01-72, none (MBX IP-300)
01-24, none (MBX IP-100)
01
INCOMING GRP NO -- Set CO Group
Number to apply to incoming calls.
4 01-72, none (MBX IP-300)
01-24, none (MBX IP-100)
01
TENANT NO -- Set Tenant group number to
apply to CO lines.
5 1-9 (MBX IP-300)
1-3 (MBX IP-100)
1
DGT CONVERT TBL -- Set Digit Conversion
Table index.
61-9 2
SIGNAL TYPE -- Set Answer Signal Type. 7 0: No Signal
1: Send Wink (IC)
2: Wait Seize Ack (OG)
3: Send Wink & Wait Sz Ack
4: Send & Wait Sans
5: Send Wink & Send Answer (IC)
6: Wait Ack & Send Answer (OG)
7: Send All & Wait All
No Signal
RLS TIMING -- If Release Timing is set to first
release, CO line is released when one party
release the call. If Caller or Called Release is
set, CO line is released when caller or called
party released the call.
8 0: First Release
1: Caller Release
2: Called Release
First RLS
Release 1.0
November 2010