Technical data

CO Group Access Code 5-4
Chapter 5: CO/IP
MBX IP Description / Operations & Programming Guide
CONDITIONS
- This feature can be set for each Outgoing CO Group.
- If CO Line has been seized directly, not using a CO Line Access Code, this feature is
not enabled.
- When Outgoing CO Group is none, a CO Line can be seized according CO Group
Access.
PROGRAMMING
Numbering Plan
CO Group Access Code (PGM 114) … see page A-22
Station Data
CO/IP Group Access (PGM 150) … see page A-45
CO Data
CO Group Access Code Attributes (PGM 180) … see page A-64
PGM 114 BTN RANGE REMARK
CO GRP ACCESS CODE (Edit By Range) 1 Start CO Grp Access Code
& End CO Grp Access Code
-
CO GRP ACCESS CODE (Edit) 2 CO Grp Access Code -
PGM 180 BTN RANGE DEFAULT
ACCESS CODE NAME -- When a CO Grp Access
code is dialed or Flex Button is pressed; name is
displayed on the station's LCD.
1 Max 16 chars -
CO LINE CHOICE -- Decide to select to CO line
priority to seize. NOTE: When Outgoing Group
Number is not assigned, this option is not applied.
2 0: Round Robin
1: Last Line
2: First Line
Last Line
OUTGOING GRP NO -- Determines the CO
Group number used to seize. NOTE: If not
assigned, the access code is used as LOOP key.
3 01-72 (MBX IP-300)
01-24 (MBX IP-100)
Not assigned to the
first access code.
01-72 (MBX IP-300)
01-24 (MBX IP-100)
is assigned
sequentially from the
second access code
Release 1.0
November 2010