Technical data
CO Group Access Code 5-3
Chapter 5: CO/IP
MBX IP Description / Operations & Programming Guide
PROGRAMMING
Numbering Plan
CO Group Access Code (PGM 114) … see page A-22
CO Line Data
CO Group Access Code AND Digit (PGM 180 - FLEX 4) … see page A-64
CO Group Access Code
The CO Group Access code can be set dynamically for each Outgoing CO Group. One
Outgoing CO Group can have several access codes. Additionally, there are various kinds of
services for each access code:
• Access Code Name – Access code name can be displayed when a user seizes a CO
line with CO Group Access code.
• CO Line Choice – There are 3 ways to seize a CO line (Round / First / Last).
• Outgoing CO Group – When a user dials a CO Group Access code, the System will
seize a CO Line with the Outgoing CO Group.
• AND – When using CO Group Access code, it can add max. 10 digits to be able to
send towards PX automatically.
• ARS Service – When a selected path is not available for some reasons(all busy, line
fault, etc), this feature connects a call using another path which is preset
automatically
PGM 114 BTN RANGE REMARK
CO GRP ACCESS CODE (Edit By Range) 1 Start CO Grp Access Code
& End CO Grp Access Code
-
CO GRP ACCESS CODE (Edit) 2 CO Grp Access Code -
PGM 180 BTN RANGE DEFAULT
AND DGT -- Automatic Network Dialing (AND) digit is sent after CO
line seized. This feature allows user to initiate CO calls only by dialing
CO Group Access Code.
4Max 10
digits
-
Release 1.0
November 2010