Technical data

Alarm Signal/Door Bell 3-4
Chapter 3: System Features
MBX IP Description / Operations & Programming Guide
To terminate an Alarm Signal while idle:
Dial the {Sys Alarm Reset Feature Code}; a confirmation tone is received and the Alarm
Signal is terminated.
OR
Press the programmed {ALARM STOP} Flex button.
NOTE: If the alarm condition is cleared, the system will automatically rearm the alarm
monitoring.
ADMIN PROGRAMMING
Station Data
Alarm (PGM 121 - FLEX12) … see details on page A-25
System
Alarm (PGM 121 - FLEX12) … see details on page A-90
RELATED FEATURES
Door Open … see page 3-78
HARDWARE
Digital Phone
External contact connected to Alarm input of MPB, refer to MBX IP Hardware &
Installation Manual.
PGM 121 BTN RANGE DEFAULT
ALARM -- enable to receive system alarm signal. 12 1-3 1
PGM 227 BTN RANGE DEFAULT
ALARM ENABLE -- enables the external contact monitoring circuitry. 1 0: Off
1: On
Off
ALARM CONTACT TYPE -- establishes the contact state that will
activate the Alarm, close or open.
2 0: Open
1:Close
Open
ALARM MODE -- the contact can be designated to function as a
doorbell instead of an alarm.
30: Bell
1: Alarm
Alarm
ALARM SIGNAL MODE -- the assigned stations will receive a
Repeating signal or single burst (ONCE) of the alarm tone.
4 0: Once
1: Repeat
Repeat
Release 1.0