Technical data

System Networking 3-204
Chapter 3: System Features
MBX IP Description / Operations & Programming Guide
RLS TIMING -- If Release Timing is set to first
release, CO line is released when one party
release the call. If Caller or Called Release is
set, CO line is released when caller or called
party released the call.
8 0: First Release
1: Caller Release
2: Called Release
First RLS
INC/OUT MODE -- Each CO lines can be set
to only incoming call is allowed or outgoing is
allowed only.
9 0: Incoming Only
1: Outgoing Only
2: Allow Both
Both
DIALING TYPE -- Signal type can be selected;
DTMF, Pulse, R2MFC.
10 0: DTMF
1: PULSE
2: R2
DTMF
CHARGE MODE -- If 'FREE', the external call
though CO line is not printed/saved to SMDR
even though SMDR is enabled.
If 'REPORT', the external call though CO, line
is included to SMDR according to the SMDR
Attributes.
11 0: Free
1: Report
Report
METERING TYPE -- According to PSTN
service type, metering type can be selected
among 00-12 to manage call charge. 01-06
can be applied to LCO lines, 07-12 can be
applied to ISDN lines.
12 00: None
01: 12KHz
02: 16KHz
03: 50KHz
04: SPR
05: PPR
06: NPR
07: AOC 0(Standard)
08: AOC 1 (Italy & Spain)
09: AOC 2 (Finland)
10: AOC 3 (Australia)
11: AOC 4 (Belgium)
12: AOC 5 (Netherlands)
None
PGM 160 BTN RANGE DEFAULT
Release 1.0
November 2010