Technical data

System Networking 3-203
Chapter 3: System Features
MBX IP Description / Operations & Programming Guide
ADMIN PROGRAMMING
Numbering Plan
System Numbering Plan (PGM 111) … see details on page A-17
CO Line Data
CO Line Attribute (PGM 160) … see details on page A-47
PGM 111 BTN RANGE REMARK
PREFIX CODE -- leading preceding digits of some
numbering plan code.
1 1-8 digits Prefix code length + more
digit can be 8 at max.
MORE DIGITS -- number of digits following the
Prefix code.
2 (0-4)
PGM 160 BTN RANGE DEFAULT
CO TYPE -- Displays physical line type of
selected CO line.
1 Display Only -
SVC TYPE -- Set CO line type as DID or
Normal.
20:Normal
1:DID
Normal
OUTGOING GRP NO -- Set CO Group
Number to apply to outgoing calls.
3 01-72, none (MBX IP-300)
01-24, none (MBX IP-100)
01
INCOMING GRP NO -- Set CO Group
Number to apply to incoming calls.
4 01-72, none (MBX IP-300)
01-24, none (MBX IP-100)
01
TENANT NO -- Set Tenant group number to
apply to CO lines.
5 1-9 (MBX IP-300)
1-3 (MBX IP-100)
1
DGT CONVERT TBL -- Set Digit Conversion
Table index.
61-9 2
SIGNAL TYPE -- Set Answer Signal Type. 7 0: No Signal
1: Send Wink (IC)
2: Wait Seize Ack (OG)
3: Send Wink & Wait Sz Ack
4: Send & Wait Sans
5: Send Wink & Send Answer (IC)
6: Wait Ack & Send Answer (OG)
7: Send All & Wait All
No Signal
Release 1.0
November 2010