Technical data

System Networking 3-202
Chapter 3: System Features
MBX IP Description / Operations & Programming Guide
- When the System detects a fatal error from the Network, the System sends digit
streams to the Network using the Alternate Dial bin (not a Net Call).
- The CO Call Restriction Timer is also applied to Net Call (PGM180 - FLEX 14).
OPERATION
To configure Net Call Numbering Plan programming:
Press [PGM] + 111 (Prefix Code) + (1) + Prefix code for Networking Numbering + [SAVE]
To perform a Net Call:
1. Lift Handset or press the [SPEAKER] button; dial tone will be provided.
2. Dial a Station number on another System, or press the {NET DSS} button for the other
System.
3. The Station seizes the network CO Line according to the Net Routing Table, and the
System sends a modified digit stream.
4. The called System receives a digit stream sent by the Calling Party, and analyzes it
using the net routing table to determine the right destination, sending it to the Called
Party (ring signal).
5. When Net Call is established, a network CO Line is used; when Net Call is cleared,
the network CO Line is released.
6. The [Network CO] button LED will be extinguished when Net Call is cleared.
Release 1.0
November 2010