Technical data

Station Message Detail Recording (SMDR) 3-184
Chapter 3: System Features
MBX IP Description / Operations & Programming Guide
CONDITIONS
- If enabled, Call Cost display begins after the SMDR Start Timer expires, or at receipt
of the first Call Meter Pulse.
- Once connected to the system, the call duration includes the total time the call is
connected including periods when the call is on hold, in queue, etc.
- To enable Call Cost Display, the SMDR Cost per Unit Pulse and SMDR Decimal must
be assigned; when not assigned, call duration is provided by the System.
- SMDR MAX record message number is 5000; alarm message is automatically
received at the Attendant Station if recorded number is 4000 or 4500.
OPERATION
System When set, Call Cost is estimated automatically and output to Digital Phone displays and
the SMDR RS-232 port.
ADMIN PROGRAMMING
CO Line Data
Metering Type (PGM 160 - FLEX 12) …see details on page A-47
PGM 160 BTN RANGE DEFAULT
METERING TYPE -- According to PSTN service type,
metering type can be selected among 00-12 to
manage call charge. 01-06 can be applied to LCO
lines, 07-12 can be applied to ISDN lines.
12 00: None
01: 12KHz
02: 16KHz
03: 50KHz
04: SPR
05: PPR
06: NPR
07: AOC 0(Standard)
08: AOC 1 (Italy & Spain)
09: AOC 2 (Finland)
10: AOC 3 (Australia)
11: AOC 4 (Belgium)
12: AOC 5 (Netherlands)
None
Release 1.0