Technical data
External Auto Attendant/Voice Mail 3-94
Chapter 3: System Features
MBX IP Description / Operations & Programming Guide
CONDITIONS
- Selection of SMDI or in-band signaling can be modified using Admin. Programming
(refer to Admin. Programming Manual).
- Only one AA/VM Group can be defined in the system; multiple definitions may cause
erroneous system operation.
- The calling number will display with SMDI CLI INFO attribute (PGM203 - FLEX 7).
OPERATION
System
The system will interface with the External AA/VM based on database assignments:
ADMIN PROGRAMMING
Station Groups
VM Group Assignment (PGM 200) … see details on page A-67
PGM 200 BTN RANGE DEFAULT
GROUP TYPE -- this entry defines the type of station group. 1 0:Not Assign
1: Terminal
2: Circular
3: Ring
4: Longest Idle
5: Voice Mail
Not Assign
GROUP NAME -- this entry defines the name of a group. 2 Max 16 chars -
TENANT NO -- this entry assigns a tenant of a station group. 3 1-9 (MBX IP-300)
1-5 (MBX IP-100)
1
TIME TABLE IDX -- Time Table index, 4 1-9 1
PICKUP OPTION -- stations can pickup group calls ringing at
other stations in the group.
50: Disable
1: All Call
2: Intercom
3: External
Disable
MEMBER ASSIGN -- this entry assigns stations as members
of a station group.
6- -
Release 1.0
November 2010