Technical data
Call Handling 1-47
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
OPERATION / SETUP
When an outside caller presses the programmed CCR digit, the system will prompt the caller
"Press 1 to search by first name", "Press 2 to search by last name". Once a 1 or 2 is pressed,
the caller will be prompted to "Enter the first 3 characters of the persons first/last name".
Once the three characters have been entered, the system will check the entered characters for
a match to the names programmed in the system (see ADMIN PROGRAMMING).
If a match is found, the system will play "transferring to [programmed name]" and transfer the
call to the station.
If more than one match is found, the system will prompt the caller:
• "for [subscriber X], press 1"
• "for [subscriber Y], press 2"
When the caller enters the appropriate digit, the system will route the caller to that associated
station.
Data Line Security
Once Data Line Security is enabled on a station, communication between the station and
another party is protected from interfering signals such as overrides and Camp-Ons to the
station.
NOTE: This feature should primarily be used for modems and fax stations.
CONDITIONS
• If an SLT station (for Data, Fax, Modem) had data line security enabled, then makes an
external call (via ISDN line), the "3.1KHz Setup" message will be sent to an ISDN CO line
instead of the speech setup message.
• If a busy station with data line security enabled receives an incoming CO call, the call is
disconnected regardless of the DID/DISA destination setting.
ADMIN PROGRAMMING
Enable Data Line Security
Data Line Security -- if value is set to ON, Override and
Camp-on from other stations are prohibited when this station
is busy.
PGM 111 + FLEX 4 + 1
(On) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
Release 3.5