Technical data
Remote IP Phone Setup E-59
Appendix E: Quick Start Topics
SBX IP 320 Programming & Operations Guide
Programming VOIP card settings from a digital keyset
This is an alternative to PCAdmin programming shown above. Disregard this section if you
have configured the IP phone using PCAdmin.
1. Enter KSU programming from the digital attendant phone
2. Press PGM
3. Dial 103 (Logical Slot Assign)
4. Press Flex Button 2 (STA)
5. What to enter will depend on what cards are installed. If there are two CHB308 cards
installed the display will show 01 02 .. .. ..
Dial 01 02 99 to assign station ports to the VOIB.
6. Save
Assign IP Address to the VoIB
1. Press PGM
2. Dial 340 (VoIB Attributes)
3. Press Flex Button 1 (IP ADDR)
4. Dial the IP Address (eg 192.168.1.10 Dial 192168010010)
5. Save
6. Press Flex Button 2 (Gateway ADDR) - Mandatory
7. Dial Default Gateway for VoIB (eg 192.168.1.1 Dial 192168001001)
8. Save
9. Press Flex Button 3 (Subnet Mask)
10. Dial Subnet Mask (eg 255.255.255.0 Dial 255255255000)
11. Save
Release 3.5
June 2010