Technical data

Call Control 1-22
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
Enable Station Account
OPERATION / SETUP
To access a CO line using an authorization code:
1. When a long warning tone sounds after dialing, enter the designated authorization
code.
2. Press # to complete the entry.
NOTE: If a five digit authorization code type (see ADMIN PROGRAMMING), you do
not need to press #. If the code entered is valid/correct, the CO line will be
connected. Otherwise, an error tone will be presented.
To register the authorization code on a station:
1. Press [TRANS/PGM], then 31.
2. Enter the authorization code, then press #.
NOTE: If a five digit authorization code type (see ADMIN PROGRAMMING), you do
not need to press #.
3. Press [HOLD/SAVE] to store the changes.
To change the authorization code at a station:
1. Press [TRANS/PGM], then 32.
2. Enter the current
authorization code.
3. Enter in the new
authorization code.
4. Press [HOLD/SAVE] to store the change.
Automatic Call Release
When a station does not complete a connection on an outgoing CO line, or receives no answer
on an intercom call, the system will disconnect the call based on assigned Auto Release Timer.
CONDITIONS
If a user station is in speaker mode, the Station returns to idle, otherwise the station will
receive an error tone if using the handset.
An Intercom call in Hands-Free mode is answered, Station Auto Release will not be
activated.
Forced Station Account Code -- if this value is set to ON, a
password is needed to access an outgoing CO line.
PGM 112 + FLEX 20 + 0
(Off) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
Release 3.5
June 2010