Technical data
Other VOIB Programming Codes B-11
Appendix B: VoIP Service
SBX IP Programming & Operations Guide
RSG/IP Phone Programming (PGM 380-397)
VOIB Slot Assignment, RSG/IP Phone (PGM 380)
The VOIB slot and VOIB channel for the RSG/IP Phone can be assigned. The RSG is serviced
through the VOIB, so the VOIB for the RSG must be assigned.
Press the [TRANS/PGM] button, dial 380, and follow the specific procedure:
RSG/IP Phone Port Number Assignment (PGM 381)
Press the [TRANS/PGM] button, dial 381, and follow the specific procedure:
VoIB H.323 ID -- used to set a unique VOIB's
ID.
PGM 341 + FLEX 14 + Value
+ [HOLD/SAVE]
VALUES --
Up to 23 characters
VoIB E164 Address -- used to set the station
number.
PGM 341 + FLEX 15 + Value
+ [HOLD/SAVE]
VALUES --
Up to 23 characters
VoIB Terminal Alias -- Reserved PGM 341 + FLEX 16 + Value
+ [HOLD/SAVE]
VALUES --
20 digits
VOIB Slot For RSP/IP Phone -- designates
the VOIB slot assignment for RSG/IP phone.
PGM 380 + FLEX 1 + 10 +
[HOLD/SAVE]
(must be slot 10)
VOIB Channel For RSG/IP Phone --
designates the VOIB Channel number used
for the RSP/IP phone.
PGM 380 + FLEX 2 + Channel
Range + [HOLD/SAVE]
Channel Range = 0-8
RSG Number -- N/A
Number of RSG to register.
Use PGM 382 Flex 2, number of IP phones.
PGM 381 + FLEX 1 n/a
IP Phone Number -- the IP Phone number to
be serviced by the system (up to 16 IP phones
can be registered on the system).
PGM 381 + FLEX 2 + IP
Phone Number +
[HOLD/SAVE]
Range = 00-16
Release 3.5
June 2010