Technical data

Other Programming Tables 1-235
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
System Timers (PGM 180-184)
System Timers 1(PGM 180)
Camp On Recall Timer -- when a call is transferred
using Camp-On to a busy station, if the transferred-to
station does not answer the call, it will recall to the
transferring station after the designated time expires.
PGM 180 + FLEX 3 + 030
Seconds (3 digits) +
[HOLD/SAVE]
VALUES --
Range = 000-200
ACNR No Tone Retry Timer -- determines the number
of attempts to secure a CO line for ACNR. If a CO line
is not seized, ACNR will be canceled.
PGM 180 + FLEX 12 + 1
Value (1 digit) +
[HOLD/SAVE]
VALUES --
Range = 1-9
CO Call Drop Warning Timer -- on prepaid CO calls,
the system will give a warning tone that designates
that the prepaid amount has been used. After the
timer expires, the call will be disconnected. This is
also used for call drop warning in Unsupervised
Conferences.
PGM 180 + FLEX 16 + 10
sec (2 digits) +
[HOLD/SAVE]
VALUES --
Range = 00-99
CO Call Restriction Timer -- N/A
If value is set to 0, the time of outgoing CO calls is not
restricted. If value is set to a non-zero value, outgoing
CO calls are disconnected after the designated time.
PGM 180 + FLEX 17 +
minutes (2 digits) +
[HOLD/SAVE]
VALUES --
Range = 00-99
CO Dial Delay Timer -- used to prevent illegal dialing
in case of slow response from the Central Office Line
or PBX.
PGM 180 + FLEX 18 + 01
Value (100 msec, 2 digits) +
[HOLD/SAVE]
VALUES --
Range = 00-99
CO Release Guard Timer - designates the amount of
time before a CO line can be re-seized, after a CO call
disconnects; controls the time necessary to
guarantee an idle loop state when a line is released.
PGM 180 + FLEX 19 + 020
Value (100 msec, 3 digits) +
[HOLD/SAVE]
VALUES --
Range = 001-150
CO Ring Off Timer -- used to designate the time
interval between incoming ringing signals so that
active ringing can be retained in the system until the
timer expires.
PGM 180 + FLEX 20 + 060
Value (100 msec, 3 digits) +
[HOLD/SAVE]
VALUES --
Range = 001-150
CO Ring On Timer -- controls the time necessary to
detect an incoming CO call ringing into the system.
PGM 180 + FLEX 21 + 2
VALUE (100 msec, 1 digit) +
[HOLD/SAVE]
VALUES --
Range = 1-9
CO Warning Tone Timer -- N/A
(For Korea only) This sets the amount of time before
receiving a warning tone as a reminder of the elapsed
call time on an outgoing CO line conversation.
PGM 180 + FLEX 22 + 180
Seconds (3 digits) +
[HOLD/SAVE]
VALUES --
Range = 060-900
Release 3.5
June 2010