Technical data

Other Programming Tables 1-228
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
ACD Print Timer Unit -- value determines the unit of
ACD print timer.
PGM 161 + FLEX 14 + 0
(Sec) + [HOLD/SAVE]
VALUES --
0 = Sec
1 = Hour
Range: 1 hr-10sec
(PGM 161 - FLEX 10)
Set VM SMDI Type -- value sets the VM SMDI type. PGM 161 + FLEX 15 + 0
(Type I) + [HOLD/SAVE]
VALUES --
0 = Type I
1= Type II
NO DSS Indication -- if value is set to ENABLE, the
LED indication of the {CO} or {DSS} button is
blocked (ex., LED does not flash even if there is an
incoming call to the assigned CO Line or Station).
This feature does not apply for direct calls such as
DID/DISA.
PGM 161 + FLEX 18 + 0
(Disable) + [HOLD/SAVE]
VALUES --
0 = Disable
1 = Enable
UK Billing Mode -- N/A
If value is set to ON, the UK Billing Mode is applied.
(UK Only)
PGM 161 + FLEX 19 + 0
(Off) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
COS 7 When Authorization Fails -- if value is set to
ON, the Station COS will temporarily be changed to
7 when an invalid authorization code is entered at
the Station. COS can be recovered by activating
COS RESTORE.
If not assigned, the day & night COS in PGM 116 will
be changed to 7 when an invalid authorization code
is entered at the station. To recover COS, day &
night COS should be reassigned.
PGM 161 + FLEX 20 + 0
(Off) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
LCR Dial Tone Detect -- if value is set to ON, the
SBX IP system first checks if the CO provides dial
tone in case if analog CO is seized for LCR dialing.
If there's no dial tone, the call is rerouted to the
Alternate DMT Index.
If LCR type is set to M13, the LCR dial tone detect
option is not applied.
PGM 161 + FLEX 22 + 0
(Off) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
Release 3.5