Technical data
Other Programming Tables 1-224
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
CO Line Attributes 3 (PGM 146)
Enter appropriate CO line range (01-12) and follow the specific procedure shown in the Table
Deny Incoming Call -- if value is set to ON, the
incoming call is disconnected.
PGM 143 + FLEX 17 + 0
(OFF) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
Drop If No CLI -- PGM 143 + FLEX 19 + 0
(OFF) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
Incoming Prefix Code Insertion -- if value is set to
ON, prefix code will be attached in front of
incoming CLI information
PGM 146 + FLEX 1 + 0
(OFF) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
Outgoing Prefix Code Insertion -- if value is set to
ON, prefix code will be attached in front of
outgoing CLI information.
PGM 146 + FLEX 2 + 1
(ON) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
ISDN Line Type -- used to set the ISDN CODEC
Type.
PGM 146 + FLEX 3 + 1
(μ-Law) + [HOLD/SAVE]
VALUES --
0 = A-Law
1 = μ-Law
Calling Sub-address -- if value is set to ON, calling
party sub-address of the ISDN station is attached
when an ISDN station makes an outgoing CO call
through this CO line.
PGM 146 + FLEX 4 + 1
(ON) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
Collect Call Blocking -- if feature is set to 1 or 2,
incoming collect calls are blocked.
PGM 146 + FLEX 7 + 0
(VALUE) + [HOLD/SAVE]
VALUES --
0 = Disable
1 = With Indicator
2 = Without Indicator
Collect Call Answer Timer -- in case of "WITHOUT
INDICATOR" collect call blocking, an incoming call
is answered during this time. Then the CO loop is
opened.
PGM 146 + FLEX 8 + 010
(VALUE) + [HOLD/SAVE]
VALUES --
1-250 (100ms 3 digits)
Collect Call Idle Timer -- case of "WITHOUT
INDICATOR" collect call blocking, an incoming call
is answered during "Collect Call Answer Timer".
Then the CO loop is opened during this time and
the CO is answered again.
PGM 146 + FLEX 9 + 020
(VALUE) + [HOLD/SAVE]
VALUES --
1-250 (100ms 3 digits)
Release 3.5