Technical data
Other Programming Tables 1-221
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
CO Line Attributes 2 (PGM 142)
Enter appropriate CO line range (01-12) and follow the specific procedure shown in the Table
Tenancy Group -- designates the ICM Tenancy
group number a CO belongs to. If value is set,
separate Day/Night ring mode is applied to
incoming CO Calls according to ICM Tenancy
group Attendant Day/Night ring mode.
PGM 141 + FLEX 10 + 0
(Tenancy Group) +
[HOLD/SAVE]
VALUES --
Range = 0-5
(see PGM 120)
CO Start Signal -- designates a loop closure or
a ground as the "connect" (start) signal on an
analog CO Line.
PGM 141 + FLEX 12 + 0
(Loop) + [HOLD/SAVE]
VALUES --
0 = Loop
1 = Ground (not US)
Metering Unit -- N/A
This designates the unit used to detect pulses from
the CO Line. There are 7 metering signal types
(refer to VALUES).
PGM 142 + FLEX 3 +
Metering Signal type +
[HOLD/SAVE]
VALUES --
00 = None
01 = 50 Hz
02 = 12 KHz
03 = 16 KHz
04 = Sing Polar Rev
05 = Plural Polar Rev
06 = No Polarity Rev
Line Drop using CPT (Call Progress Tone) -- if value
is set to ON, CPT checks the incoming CO Line
when answered and if CPT detects a dial tone, the
system should drop the line for toll restriction.
PGM 142 + FLEX 4 + 0
(Off) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
PABX CO Dial Tone -- if value is set to YES, PX or
PABX provides the CO Dial Tone; otherwise, the
SBX IP system provides it.
PGM 142 + FLEX 7 + 0
(No) + [HOLD/SAVE]
VALUES --
0 = No
1 = Yes
PABX CO Ring Back Tone -- if value is set to YES,
PX or PABX provides a CO Ring Back Tone;
otherwise, the SBX IP system provides it.
PGM 142 + FLEX 8 + 0
(No) + [HOLD/SAVE]
VALUES --
0 = No (System)
1 = Yes (PBX)
PABX CO Error Tone -- if value is set to YES, PX or
PABX provides a CO Error Tone; otherwise, the
SBX IP system provides it.
PGM 142 + FLEX 9 + 0
(no) + [HOLD/SAVE]
VALUES --
0 = No (System)
1 = Yes (PBX)
PABX CO Busy Tone -- if value is set to YES, PX or
PABX provides the CO Busy Tone; otherwise, the
SBX IP system provides it.
PGM 142 + FLEX 10 + 0
(NO) + [HOLD/SAVE]
VALUES --
Default = NO
0 = No (System)
1 = Yes (PBX)
Release 3.5