Technical data
Software Upgrade 1-198
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
Serial (COM port)
The MBU software can be upgraded via through an RS-232C serial interface using the ipLDK
upgrade program stored within a remote computer.
CONDITIONS
• The Serial port MUST be connected to COM port 2 in the MBU.
• While in the upgrade process, other features do not work in the system.
• When the SBX IP MBU software upgrade is finished without completing, you can retry to
upgrade by doing the whole process again.
• If the ROM files you want to send are invalid, the MBU s/w upgrade will not be started.
ADMIN PROGRAMMING
Set RS-232C Port
RS-232C Port Setting -- used to designate port
settings and assign: Baud Rate, CTS/RTS,
P-Break, and LPP.
COM1
PGM 174 + FLEX 1 + FLEX 1 + 6
(19200, Baud rate) + [HOLD/SAVE]
COM2 (MODU Port)
PGM 174 + FLEX 2 + FLEX 1 + 6
(19200, Baud rate) + [HOLD/SAVE]
VALUES --
COM1-COM2
(Flex 1-4)
FLEX 1-FLEX 4
(refer to Table)
FLEX SETTING VALUE DEFAULT
1 BAUD RATE 0: n/a
1: n/a
2: 1200 Baud
3: 2400 Baud
4: 4800 Baud
5: 9600 Baud
6: 19200 Baud
7: 38400 Baud
19200
2 CTS/RTS On/Off Off
3 P-BREAK On/Off Off
4 LPP 001-199 060
Release 3.5
June 2010