Technical data

Software Upgrade 1-198
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
Serial (COM port)
The MBU software can be upgraded via through an RS-232C serial interface using the ipLDK
upgrade program stored within a remote computer.
CONDITIONS
The Serial port MUST be connected to COM port 2 in the MBU.
While in the upgrade process, other features do not work in the system.
When the SBX IP MBU software upgrade is finished without completing, you can retry to
upgrade by doing the whole process again.
If the ROM files you want to send are invalid, the MBU s/w upgrade will not be started.
ADMIN PROGRAMMING
Set RS-232C Port
RS-232C Port Setting -- used to designate port
settings and assign: Baud Rate, CTS/RTS,
P-Break, and LPP.
COM1
PGM 174 + FLEX 1 + FLEX 1 + 6
(19200, Baud rate) + [HOLD/SAVE]
COM2 (MODU Port)
PGM 174 + FLEX 2 + FLEX 1 + 6
(19200, Baud rate) + [HOLD/SAVE]
VALUES --
COM1-COM2
(Flex 1-4)
FLEX 1-FLEX 4
(refer to Table)
FLEX SETTING VALUE DEFAULT
1 BAUD RATE 0: n/a
1: n/a
2: 1200 Baud
3: 2400 Baud
4: 4800 Baud
5: 9600 Baud
6: 19200 Baud
7: 38400 Baud
19200
2 CTS/RTS On/Off Off
3 P-BREAK On/Off Off
4 LPP 001-199 060
Release 3.5
June 2010