Technical data
Hunt Groups 1-115
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
RING HUNT GROUP ATTRIBUTES
Overflow Timer -- if timer expires after a call is
received in the group, the call will be routed to the
overflow destination.
PGM 191 + FLEX 8 + 180
seconds + [HOLD/SAVE]
VALUES --
Range = 000-600
Wrap-up Timer -- is used to delay new calls to a
member of the Hunt Group that has just become idle.
PGM 191 + FLEX 9 + 002
seconds + [HOLD/SAVE]
VALUES --
Range = 000-999
Music Source -- if a music source is assigned, user
will be able to hear music instead of a ring back tone
PGM 191 + FLEX 10 + 0
Music Source (refer to
Values) + [HOLD/SAVE]
VALUES --
0 = not assigned
1 = Internal Music
2 = External Music
3 = n/a
4-8 = SLT MOH
Max Queue Count -- if no members are on duty or all
members are busy, incoming CO calls will be queued.
The Hunt Group Supervisor will be able to see the
queued incoming call count until the max queue count
is attained.
PGM 191 + FLEX 11 + 99
(Value, 2 digits) +
[HOLD/SAVE]
VALUES --
Range = 00-99
VMIB Supervisor -- PGM 191 + FLEX 12 +
Value (Sta Number) +
[HOLD/SAVE]
VALUES --
Range = 100-131
Hunt Member Forward -- OFF is receive Hunt Call,
ON is not receive Hunt Call.
PGM 191 + FLEX 13 + 1
(On) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
Queue Count Display -- if value is set to ON, a Hunt
Group member can check the Queue Count.
PGM 191 + FLEX 14 + 1
(On) + [HOLD/SAVE]
VALUES --
0 = Off
1 = On
Release 3.5
June 2010