Technical data
Internet Protocol (H.450) 141
SBX IP 320 Features & Operation Guide
Operation
To set the [Transit-Out Security] Option:
1. Press PGM 161 - FLEX 23.
2. Set ON or OFF.
Operation Step:
1. Setup packet for transit-out arrives from VOI line.
2. If the transit-out security option is set, the system searches for a registered IP in Net
Number tables.
3. If received IP does not match with any registered IP in the Net Number Table, the call
will be disconnected.
4. When a matched IP is found, the transit-out feature will be invoked.
Conditions
• To set the transit-out security function, set the [Transit-Out Security] Admin and set IP
numbers at CPN Info in Net Number Table.
• Transit-Out Security Check is only used at a VOI CO line.
Programming
• PGM 161 - FLEX 23
VOIP Networking
Two SBX IP 320 Systems can be connected through the VOIB. The networking CO line
connects the networking Systems and it is used for the network signaling message and voice
path. To use the networking CO line, the service type must be set to DID/MSN at PGM 140.
And to receive the net call digit information correctly, the appropriate DID conversion type must
be set at PGM 143 - FLEX 4. In the following example, DID TYPE 1 satisfies the situation. To
configure the net CO line connection, the net CO group and type must be set to '01' and 'NET'
at PGM 322 - FLEX 1 & 4.