Installation guide

PMS Messages 9-13
Chapter 9: Hotel - Property Management System (PMS)
MBX IP Hardware & Installation Guide
Wake Up Registration
Byte Order Contents Value & Description
0
1
Message Length (Low)
(High)
0x12(18)
0x00
2 Packet Sequence Number 0x00 - 0xff
3 PMS Type 0x01
4 Feature Code 0x21
5 Direction 0x00 (MBX IP
PMS)
0x01 (MBX IP
PMS)
6 - 9 Room Telephone Number
1
(Start) 2
3
4
Exe1) 1234 Exe2) 1200
0x12 0x12
0x34 0xAA
0xFF 0xFF
0xFF 0xFF
10 - 13 Room Telephone Number
1
(End) 2
3
4
0xFFFFFFFF if phone number does not exist
14 Wake Up Type 0x00 : Cancel
0x01 : once
0x02 : every day
15 - 16 Wake Up Time
1
2
HH:MM
HH
MM
17 Input Location 0x01 : PMS
0x02 : Hotel Attendant
0x03 : Front Desk D-TEL
0x04 : WEB ADMIN
0x05 : General Station
Release 1.7