The 9 LEDs mounted on the MBX IP WTIB4/8 provide diagnostic information for status of the
board. The following table shows the meaning of the different LED status indicators.
Switch Functions
NOTE: TBR6 test mode needs not to be set for normal operation because TBR6 test mode is used only
for DECT confirmation test.
LED Indications
SW ON OFF DESCRIPTION DEFAULT
SW3-1 TBR6 test mode Normal Reserved for test OFF
SW3-2 Enable Echo-can. Disable Echo-can. Echo-canceller control ON
SW3-3 NOT USED NOT USED NOT USED ON
SW3-4 All base reset Only new base reset On: All base reset Off: One base reset OFF
LED NORMAL LABEL
1 ON: Master WTIB, Toggle: Slave 1 WTIB, OFF: Slave 2 WTIB M/S
2 When Nios CPU is normal, TMR LED toggles every 100msec. TMR
3 ON: DSP Echo cancellation enabled, OFF: DSP Echo cancellation disabled DSP
4 When more than one DECT channel is used, LED8 is ON. IN USE
5 When WTIB is connected with MPB, CON LED is ON. CON
6 When WTIB sends or receives data from MPB, IP LED toggles. IP
7 When WTIB sends or receives data from Base Station, E1 LED toggles. E1
8 When WTIB sends or receives data from other WTIB, WBUS LED toggles. WBUS