Specifications

- 31 -
DX-120 Installation and Maintenance Manual OVERVIEW
DSS Console (continued)
The DSS has 64 programmable buttons with dual color (red / green) LEDs and may be assigned any system
feature code or directory number. These buttons may be assigned for either system features operations or
CO line access operations.
You can mount the DSS console in one of three positions: low and low profile desk positions and the wall
mounted position. DSS consoles are programmed to operate with an associated speakerphone.
You can assign up to four DSS consoles per speakerphone. The maximum number of DSS consoles
supported by the DX-120 is 12.
Each equipped DSS console requires one digital port, therefore the total number (system capacity) of
speakerphones possible is reduced by one for each DSS console installed.
Specifications
CURRENT DRAW
Use this chart to calculate the Amphour requirements of the DX-120 system based upon its configuration. This
information is typically used to apply UPS battery requirements.
Specifications (continued on next page)
Component
Current Draw
(Amps) @ 117
VAC
Quantity
Extended
Total Amps
KSU1 (7201) 0.18A 1 0.18A
KSU2 (7202) 0.17A 1 max.
COM4 (7210) 0.02A 2 max.
DPM8 (7220) 0.01A 4 max.
APM4 (7230) 0.08A 3 max.
MDM (7249) 0.01A 1 max.
AAM (7240) 0.01A 1 max.
7271C 0.02A 1 max.
7270C 0.01A 1 max.
DET (7261-00) 0.016A 80 max.
DSS (7262-00) 0.016A 12 max.
Station wire:
per DET, DSS, and IST
0.02A every 100
ft. of 24AWG
?
Multiply the unit times the quantity installed in the subject application (site) and add the right
column for the total current draw (Amps) @ 117VAC for this site.