Specifications

- 117 -
DX-120 Installation and Maintenance Manual TROUBLESHOOTING INSTALLATION ISSUES
Invalid Entries Calling a Busy Station
(Issues with Multiple Mailbox Greetings)
SOLUTION: THE FOLLOWING ITEMS SHOULD BE APPLIED TO ALL DX-120 (PC8 IN-SKIN)
VOICE MAIL SYSTEMS; BUILD 8.5.9 AND EARLIER.
1) Add the new TRANS.TXT file – 8.5.9.
NOTE
R41 does not support multiple mailbox greetings (all users should use
greeting 0).
All characters must be entered as shown for proper programming.
Commands in bold indicate changes to previously documented
material, and are not to be entered as bold.
All of these changes have been incorporated in build 8.5.10.1 and later.
;Direct call (internal)
a1b1czdx=x*,*,#
;Direct call (external)
a1b2czdx=
;Transfer from operator (internal)
a2b1czdx=x*,*,1,1
;Transfer from operator (external)
a2b2czdx=x*,*
;Busy call forward
*a3byczdx=x*,*
a3byczdx=x*,*
;No answer call forward
a4byczdx=x*,*
;Direct call forward
a5byczdx=x*,*
;Record
a6byczdx=x*,*,1,1:n
;Individual greeting for trunk 1-8
a7byczd800=
a7byczd801=
a7byczd802=
a7byczd803=
a7byczd804=
a7byczd805=
a7byczd806=
a7byczd807=;Recall (from Hold / No ans)
a8byczdx=x*,*
;UCD re-route for UCD groups 1-5
a9byd13=3301
a9byd23=3302
a9byd33=3303
a9byd34=3304
a9byd05=3305
(continued on next page)