Programming instructions

- 35 -
DX-120 Programming Manual SHORTCUTS THAT HELP YOU WORK FASTER
Copy the Programmed Baseline Extension Setups via the DET (continued)
Copy Individual Extension Settings
3) Enter 08-12-01.
4) Press save to display the “INDIVIDUAL COPY” programming screen.
5) Press show to display the prompt: “COPY FROM”.
6) Enter the extension directory number you want to use as a baseline.
7) Press save to display the prompt: “COPY TO”.
8) Enter the extension number into which you want to copy the baseline setups into.
9) Press save to store the copy and again display the prompt “COPY TO”.
• Use the steps above to copy other extensions as needed.
• Press save each time you copy an extension.
10) Press the Hold button to return to the previous menu level.
OR
Press the Volume button (up or down) to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27).
Copy All Lines in a Pickup Group
1) Enter 08-12-02.
2) Press save to display the “GROUP COPY” programming screen.
3) Press show to display the prompt: “COPY FROM”.
4) Enter the extension directory number you want to use as a baseline.
5) Press save to display the prompt: “COPY TO”.
6) Enter the pickup group number into which you want to copy the baseline setups into.
7) Press save to copy the programming of the baseline extension into all the extensions in the specified
pickup group and again display the prompt: “COPY TO”.
• Use the steps above to copy programming to other pickup groups.
8) Press the Hold button to return to the previous menu level.
OR
Press the Volume button (up or down) to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27).