Assigning Extensions to a Class of Service via PC-DBA (continued)
5) Click the Update button to enter and save your settings into the database on your local disk.
• Program daytime and evening class of services to other extensions (as needed) using the steps above.
When all assignments have been made:
6) Click the Close button to exit the current screen and return to the PC-DBA main screen.
Once all database changes have been completed:
7) Perform a SEND to copy the database changes to the DX-120 switch system memory.
ASSIGNING EXTENSIONS TO A CLASS OF SERVICE VIA THE DET
NOTE
chg, bksp, save, one, always, del, and ack are interactive LCD button operations.
Use the three buttons below the LCD display to activate the associated operation.
You can press Hold at any time to return to the previous level or press the volume
buttons to return to the main DB selection screen.
1) Enter Database Administration (see page 26) using the feature code Feature # * to display the password
prompt.
2) Enter the DB Admin password (see page 27).
3) Press show to display the DB Item Select screen.
4) Press next to display each of the extension COS screens (see each section below for programming
information for each).
Setting the Daytime COS for an Extension:
From the DB Item Select screen (see steps 1 through 3 above):
4) Enter 01-XXX-05 (where XXX is the extension: 101~204).
5) Press save to display the Daytime COS screen.
6) Press chg until the COS you want to assign appears.
• Valid choices are 0 through 7.
• The default is class of service 0.
7) Press next to display the Evening COS screen (now go to step 6 in “Setting the Evening COS for an
Extension:” below).
OR
Press the volume UP button to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27).