Programming instructions

SHORTCUTS THAT HELP YOU WORK FASTER DX-120 Programming Manual
- 32 -
Copy the Programmed CO Line Setup via the DET (continued)
Copy CO Lines One at a Time
3) Enter 08-11-01.
4) Press save to display the Individual CO Line Copy screen.
5) Press show to display the prompt: “COPY FROM”.
6) Enter the CO line directory number you want to use as a baseline.
7) Press save to display the prompt “COPY TO”.
8) Enter the CO line directory number you want to copy the baseline’s programming into (800-839).
9) Press save to store the copy and again display the prompt “COPY TO”.
• Continue entering CO line directory numbers CO lines to which you want to copy the baseline setups.
• Press save each time you enter a directory number.
10) Press the Hold button to return to the previous menu level.
OR
Press the Volume button (up or down) to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27).
Copy a CO Line Setup to All the Lines in a Line Group
3) Enter 08-11-02.
4) Press save to displays the Group CO Line Copy screen.
5) Press show to display the prompt: “COPY FROM”.
6) Enter the CO line directory number you want to use as a baseline.
7) Press save to display the prompts “COPY TO”.
8) Enter the CO line group directory number into which you want to copy the baseline’s programming (9,
740-746).
9) Press save to store the setups to all of the CO lines that are part of that CO line group.
• The system prompts “COPY TO” again so that you can save the setups to another line group if desired.
• Continue entering CO line group directory numbers where you want to save the baseline setup.
• Press save each time you enter a CO line group directory number.
10) Press the Hold button to return to the previous menu level.
OR
Press the Volume button (up or down) to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27).
Copy the Baseline Setups (continued on next page)