Programming instructions

PROGRAMMING UCDS DX-120 Programming Manual
- 356 -
Programming UCDs via the DET (continued)
Setting the UCD Overflow Count:
From the DB Item Select screen (see steps 1 through 3 on page 349):
4) Enter 06-01-XX-11 (where XX represents the UCD group: 01~24).
5) Press save to display the Overflow Count screen for the specified UCD group.
6) Press chg.
7) Enter the number of times you want the system to play the contents of the Overflow 2 Destination (RAD)
for this UCD group.
• The valid options are from 1 to 255 times.
• The default is 1.
NOTE
The system removes the call from this UCD queue once it plays the announcement
the number of times you specify here.
8) Press save to store the setting.
9) Press next to display the UCD Reroute Destination screen (now to go step 6 in the next section).
OR
HINT
If you want to set the Overflow Count for other UCD groups, press the volume Up
button to return to the DB Item Selection screen, and repeat the steps in this section.
Press the volume UP button to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27).
Programming UCDs via the DET (continued on next page)